WELCOME TO MEDIC2000.COM.AU

We would like to introduce you to our range of TENS and EMS machines. These machines are personal portable devices that are battery operated and, on some models, battery and mains power operated via a power-pack adaptor. These machines are pulse generators that send electrical impulses, via electrode pads, to the body, directed to reaching the nerves and also underlying muscle groups. This may help with pain control and muscle recovery.

EV-906B - CHRISTMAS 2020 SPECIAL - $199.00

CLICK TO BUY

MEDIC 2000 EV-906B (4) Channel Digital Machine comes with 4 Cable leads, Batteries, Heavy Duty Mains Power Adaptor, 25 Pads, Instruction Manual plus a medically approved carry case. The 4th Edition 2020 model has 8 modes for Manual Programs, 37 Pre-Set Programs for a total of 45 Programs. There are 5 Pre-Set Pelvic Programs.


The EV-906B Digital TENS/EMS is a battery and/or mains power operated pulse generator that sends electrical impulses, via electrode pads, to the body directed to reaching the nerves and underlying muscle group. This unit is a combination stimulator of TENS and EMS which can be used for muscle stimulation and/or pain relief.
 

The machine is provided with four controllable output channels, each independent of each other. An electrode pad pair can be connected to each and every output channel.
 

The intensity level is controlled by press buttons and read on the LCD digital display. TENS EMS therapy is an internationally accepted drug free method of pain relief & injury recovery.
 

The manufactures representative is in Australia & this is an Australian import. The Australian representative (company) has a TGA Certificate.

Your Private Health Insurance Fund may give a rebate on this machine.
 

FEATURES:
 

■   Precise Intensity Control
There are 100 steps of intensity level controlled by press buttons from 1 to 100mA.

 

■   Press Button Contro
The power, intensity level and parameter are controlled by press
buttons, which is easy for the users to adjust the settings. All of the buttons are protected by a swing out cover to avoid accidental touch.

 

■   Large Liquid Crystal Displa
A large 6.1 x 4.4 cm LCD. Showing the intensity level, settings and treatment timer. The selected modes and parameters are readable
.

■   Two Treatment Timers
There are two individual timers controlling the output of CH1, CH2 & CH3, and CH4. This function is ideal when two patients accept treatment with the same machine.

■   Treatment Time Countdown
The output will shut off automatically when time is up.

 

■   Compliance Meter
The unit can store 60 sets of records of operation.

 

■   Professional Medical Device
This is a professional unit not a toy.

25 Pad Set

Click here for Quality Management Certificate. 

WOW! NOW 25 PADS PER KIT!!
Click here for PAD PLACEMENT DIAGRAM
Click here
 for PAD POSITION PHOTOS


TECHNICAL INFORMATION:
 

ELECTRICAL SAFETY CERTIFICATE NSW20945 C TICK N692
 

1 -  Channels, Four, isolated between channels.
 

2 -  Pulse Amplitude, Adjustable, 0-100 mA peak into 500 ohm load each channel.

 

3 -  Wave Form, Asymmetrical Bi-Phase Square Pulse.

 

4 -  Voltage, 0 to 50V (Load: 500 ohm).
 

5 -  Power Source, Four 1.5V AA batteries and / or mains poweradaptor.

 

6 -  Size, 13.8cm (L) x 7.8cm (W) x 2.8cm (H).

 

7 -  Weight, 425 grams with battery.

 

8 -  Pulse Rate, Adjustable, from 2 to 150 Hz, 1 Hz/step.

 

9 -  Pulse Width, Adjustable, from 50 to 400 microseconds, 10 μs / step.

 

10 -  On Time, Adjustable, 2~90 seconds, 1 Sec. / step.

 

11 -  Off Time, Adjustable, 0~90 seconds, 1 Sec. / step.
 

12 -  Ramp Time, Adjustable, 1~8 seconds, 1 Sec. / step. The "On" time will increase and decrease in the setting value,
 

13 -  Modes, Five TENS Modes: B (Burst), N (Normal), M (Modulation), SD1 & SD2 (Strength Duration),
 

14 -  Burst Mode (B), Burst rate: Adjustable, 0.5 ~ 5Hz Pulse width adjustable, 50~300μs. Frequency fixed = 100 Hz.
 

15 -  Normal Mode (N), Pulse rate and pulse width are adjustable. 
 It generates continuous stimulation based on the setting value.

 

16 -  Modulation Mode (M). Modulation mode is a combination of pulse rate and pulse width modulation.  The pulse rate and width are automatically varied in a cycle pattern. The pulse width is decreased by 50% from its original setting in 0.5 second, and then the pulse rate is decreased by 50% from its original setting in 0.5 second. Total cycle time is 1 second. In this mode, pulse rate (2-150Hz) and pulse width (50-300μs) are fully adjustable.
 

17 -   SD1 Mode, The SD1 (Strength-Duration) mode consists of automatic modulation intensity and pulse width in 40% range. 
The intensity is always increasing while the pulse width is decreasing and vice-versa. The intensity is decreased by 40% while the pulse width is increased by 40% in 5 seconds. In the next 5 seconds, the intensity is increased by 40% while the pulse width is decreased by 40%.Total cycle time is 10 seconds. Pulse rate (2~150Hz) and pulse width (50~300μs) are fully adjustable.

 

18 -   SD2 Mode, The SD2 (Strength-Duration) mode consists of automatic modulation intensity and pulse width in 70% range.  The intensity is always increasing while the pulse width is decreasing and vice-versa. The intensity is decreased by 70% while the pulse width is increased by 70% in 5 seconds. In the next 5 seconds, the intensity is increased by 70% while the pulse width is decreased by 70%.Total cycle time is 10 seconds. Pulse rate (2~150Hz) and pulse width (50~300μs) are fully adjustable.
 

19 -  Constant Mode (C), Constant stimulation based on setting value. Only pulse width, pulse rate and timer are adjustable in this mode. "Constant" is equal o the “Normal" mode of a TENS unit.
 

20 -  Synchronous Mode (S), Stimulation of both channels occurs synchronously. The "ON" time including "Ramp Up" and “Ramp Down" time. Therefore, the setting of ON Time should be no less than two times of the "Ramp" time in this mode. ON TIME≧Ramp up + Ramp down.
 

21 -  Alternate Mode (A), the stimulation of the CH2 will occur after the 1st contraction of CH1 is completed. In this mode, the setting of ON Time should be no less than two times of the "Ramp" time. The OFF Time should be equal or more than the ON Time. ON TIME >Ramp up + Ramp down OFF TIME ≧ON TIME
 

22 -  Timer Two Adjustable timers, from 1 to 60 minutes or Continuous.  Adjustable in 1 minute each step from 1 to 15 minutes, and 5 minutes each step from 15 to 60 minutes. Treatment time countdown automatically.
 

23 -  Patient Compliance Meter, This unit can store 60 sets of operation records.   Total recorded time is 999 hours.
 

24 -  Low Battery Indicator, A low battery indicator will show up when the battery is low.
 

25 -  Operating Condition, Temperature: 0℃~40℃Relative Humidity: 30%~75%